ECOM EN3-F
Compact Portable Combustion Analyzer
The ECOM-EN3-F is a compact portable combustion analyzer, offering features found on larger, more expensive units. Housed in a rugged aluminum frame and hard-side case, the EN3-F measures up to 4 gases, from O2, CO, NO, NO2, plus probes for temperature and stack draft / pressure. The EN3-F also calculates CO2, efficiency and excess air. A strong, internal pump and peltier gas cooler with automatic condensate drain ensures proper sample conditioning, leading to better accuracy and longer sensor life.

 

 

An on board printer, SD Memory Card and wireless Bluetooth are standard features. Common applications for the ECOM-EN3-F include set-up, maintenance and emission monitoring of natural gas, diesel, and oil fired boilers, burners, and reciprocating engines. The compact size, simple operation, and long battery life (6-8 hours) make the ECOM-EN3-F a perfect tool for field technicians.

 

Standard Features
·  Up to 4 Electrochemical Sensors
·  Sensor Options: O2, CO, NO & NO2
·  Data Logging with Memory Card
·  USB Interface
·  On-Board Printer
·  15-foot Standard Sample Line*
·  CO Purge Pump to Prevent Oversaturation
·  Peltier Cooler Sample Conditioner
·  Peristaltic Pump for Automatic Moisture Removal
·  Flue Gas, Ambient, & Sensor Temperature Sensors
·  Bluetooth Link
·  Averaging Tests
·  CO2, Efficiency, Losses, Excess Air, & O2 Correction Calculations
·  1-foot Inconel Probe*
* Other lengths available. Please ask an RJ Mann sales associate for details.

 

Optional Add-ons
  ·  Calibration Gas Kit
  ·  Soot Test Probe
  ·  1-ft Flex Tip Probe
  ·  e-Comply Software

 

How does it work?
Each sensor has a circuit housed within an electrolyte solution and when the target gas is introduced into the sensor, the half reactions (oxidation and reduction) at the electrodes generate a flow of current through the circuit. The voltage drop across the electrodes is measured by the analyzer and corresponds directly to the target gas concentration (i.e., the higher the concentration of gas, the more reactions that take place, the higher the current). In each of the electrochemical sensors we use, there is also a third reference electrode which maintains a baseline potential for increased accuracy.

 

What is included with the ECOM-EN3-F Package?
  ·  Instrument with carrying case
  ·  15-foot sample line
  ·  1-foot probe with pistol grip
  ·  On-board printer
  ·  In-line filters
  ·  Particulate filters (10pk)
  ·  Roll of printer paper
  ·  Calibration magnet
  ·  Torx wrench L-shaped (size 10 )
  ·  Water trap drain tubing
  ·  External power cord
  ·  ECOM folder with instruction manual & calibration certificate

 

What testing applications can the ECOM-EN3-F be used for?
Set-up, maintenance and emission monitoring of natural gas, diesel, and oil fired boilers, burners, and reciprocating engines.

 

What does the ECOM-EN3-F measure?
O2 (0-21 %); CO (0-4000 ppm), T-Gas (0-500 °C), T-Air (0-99 °C), pressure (± 100 hPa), differential temperature, differential pressure Sensor Options: NO (0-5000 ppm), NO2 (0-1000 ppm), SO2 (0-5000 ppm), CO ppm (extended range: 0-10.000 ppm), CO% (0-63.000 ppm).